6. Calibrate sprayer
a. Using a calibrated jug, measure
the output from at least four nozzles or at least one from each boom
section, and compare with the calculated nozzle output.
b. if the output differs by a small
amount from the calculated output, alter the pressure accordingly and
repeat the calibration until you have established the correct
pressure for the required application rate.
c. If the output differs by a large
amount, re-check calibration and calculations and change the nozzle
size and/or forward speed if necessary.
< 22 > |